FLAME detectors |
|
Please click the pictures for further details or contact us and they will be e.mailed to you. |

|
Last updated - 25 June 2010 |
|
Intronics |
|
16501 (IR²) |

|
16581 (IR²) |

|
16511 (IR²) |
|
16541 (IR²) |

|
SB Adaptor |
|
SB Swivel Mount |
|
S. Steel Adj. Mount |
|
16502 (IR) |

|
Rear Viewing |
|
16500 (IR) |
|
16580 (IR) |
|
760 (IR5) |
|
860 (UV-IR²) |
|
660 (UV) |
|
16591 (UV-IR²) |
|
HIGH SPECIFICATION FLAME & SPARK DETECTORS
(Most of the following Flame Detectors are certified to EN54 10)
|
|||
|
Model |
Brief Description |
Suggested Applications |
Hazardous Area Certification |
|
IR²
16551 |
Similar in appearance to 16501. IR² Flame Detector with Glass Reinforced Polycarbonate housing to IP65. Requires SB Swivel Mount. |
Power Generation - Waste Handling - Spray Booths - Warehouses - Automotive - Fuel & Oil Storage - Printing & many others. |
Intrinsically Safe (IS), certified to ATEX II 1 G and CENELEC / IEC EEx ia IIC T4
|
|
IR²
16571 |
Similar in appearance to 16581. IR² Flame Detector with Die Cast Zinc Alloy (ZA12) housing to IP65. Requires SB Swivel Mount & SB Adaptor. |
As above |
Intrinsically Safe (IS), certified to ATEX II 1 G and CENELEC / IEC EEx ia IIC T4 |
|
IR²
16501 |
IR² Flame Detector Requires SB Swivel Mount. with Glass Reinforced Polycarbonate housing to IP65. Requires SB Swivel Mount. |
As above |
None |
|
IR²
16581 |
IR² Flame Detector with Die Cast Zinc Alloy (ZA12) housing to IP65. Requires SB Swivel Mount & SB Adaptor. |
As above |
None
|
|
IR²
16511 |
IR² Flame Detector with Copper Free Aluminium Alloy LM25 housing to IP66. Requires Stainless Steel Adjustable mount. |
As above |
Housing Atex certified to II 2 G D and CENELEC / IEC to EEx d IIc T6 |
|
IR²
16541 |
IR² Flame Detector with 316 Stainless Steel housing to IP66. Requires Stainless Steel Adjustable mount. |
As above |
Housing Atex certified to II 2 G D and CENELEC / IEC to EEx d IIc T6 |
|
IR³
16509
|
Similar in appearance to 16501. IR³ Flame Detector with Glass Reinforced Polycarbonate housing to IP65. Requires SB Swivel Mount. |
Tunnels, Atria, Power Generation - Waste Handling - Spray Booths - Warehouses - Automotive - Fuel & Oil Storage - Printing & many others. |
None |
|
IR³
16589 |
Similar in appearance to 16581. IR³ Flame Detector with Die Cast Zinc Alloy (ZA12) housing to IP65. Requires SB Swivel Mount & SB Adaptor. |
As above |
None |
|
IR³
16559 |
Similar in appearance to 16501. IR³ Flame Detector with Glass Reinforced Polycarbonate housing to IP65. Requires SB Swivel Mount. |
As above |
Intrinsically Safe (IS), certified to ATEX II 1 G and CENELEC / IEC EEx ia IIC T4
|
|
IR³
16579 |
Similar in appearance to 16581. IR³ Flame Detector with Die Cast Zinc Alloy (ZA12) housing to IP65. Requires SB Swivel Mount & SB Adaptor. |
As above |
Intrinsically Safe (IS), certified to ATEX II 1 G and CENELEC / IEC EEx ia IIC T4 |
|
IR³
16519 |
Similar in appearance to 16511. IR³ Flame Detector with Copper Free Aluminium Alloy LM25 housing to IP66. Requires Stainless Steel Adjustable mount. |
As above |
Housing Atex certified to II 2 G D and CENELEC / IEC to EEx d IIc T6 |
|
IR³
16519UL |
Similar in appearance to 16511. IR³ Flame Detector with Copper Free Aluminium Alloy LM25 housing to NEMA 4 & 4X. Requires Stainless Steel Adjustable mount. |
As above |
UL have certified the detector housing for compliance to US standards NEC500 and NEC505. UL File Number FTQH.E228526 |
|
IR³
16549 |
Similar in appearance to 16541 IR³ Flame Detector with 316 stainless steel housing to IP66. Requires Stainless Steel Adjustable mount. |
As above |
Housing Atex certified to II 2 G D and CENELEC / IEC to EEx d IIc T6 |
|
IR5 |
The Omniguard Model 760 is the most advanced multi-spectrum IR5 flame detector in today's market. In a breakthrough technological advance, the Model 760 senses infrared radiation in five discreet infrared wavelengths. for early fire detection. Requires SB Swivel Mount. |
As above |
FM, CSA, and ATEX approved. NEMA 4X weatherproof, dust-tight, watertight (IP66). Microprocessor-controlled operation incorporating patented Fire Event Analysis. |
|
UV-IR²
860 |
By combining ultraviolet and infrared sensors with micro-circuit technology, Omniguard engineers have achieved the highest possible levels of sensitivity and reliability. Requires SB Swivel Mount. |
Aircraft Hangars, Tunnels, Atria, Power Generation - Waste Handling - Spray Booths - Warehouses - Automotive - Fuel & Oil Storage - Printing & many others. |
FM, CSA, and ATEX approved. NEMA 4X weatherproof, dust-tight, watertight (IP66). Microprocessor-controlled operation incorporating patented Fire Event Analysis. |
|
UV-IR²
16531 |
Similar in appearance to 16501. UV-IR² Flame Detector with Glass Reinforced Polycarbonate housing to IP65. Requires SB Swivel Mount. |
|
None |
|
UV-IR²
16591 |
Similar in appearance to 16581. UV-IR² Flame Detector with Die Cast Zinc Alloy (ZA12) housing to IP65. Requires SB Swivel Mount & SB Adaptor. |
As above |
None |
|
UV-IR²
16291 |
Similar in appearance to 16581. UV-IR² Flame Detector with Die Cast Zinc Alloy (ZA12) housing to IP65. Requires SB Swivel Mount & SB Adaptor. For continuous operation at temperatures up to 85°C. |
As above |
None |
|
UV-IR²
16521 |
Similar in appearance to 16511. UV-IR² Flame Detector with Copper Free Aluminium Alloy LM25 housing to IP66. Requires Stainless Steel Adjustable mount. |
As above |
Housing Atex certified to II 2 G D and CENELEC / IEC to EEx d IIc T6 |
|
UV-IR²
16221 |
Similar in appearance to 16511. UV-IR² Flame Detector with Copper Free Aluminium Alloy LM25 housing to IP66. Requires Stainless Steel Adjustable mount. For continuous operation at temperatures up to 85°C. |
As above |
Housing Atex certified to II 2 G D and CENELEC / IEC to EEx d IIc T6 |
|
UV-IR²
16291 |
Similar in appearance to 16541. IR² Flame Detector with 316 Stainless Steel housing to IP66. Requires Stainless Steel Adjustable mount. |
As above |
Housing Atex certified to II 2 G D and CENELEC / IEC to EEx d IIc T6 |
|
UV
660 |
The micro-processor controlled Model 660 Ultraviolet Flame Detector offers the highest level of UV flame detection available today. They have the capability to operate at extremely high temperatures (125° C) and have a response time of 15 milleseconds. |
Turbine Enclosures Generator Rooms Munitions Facilities Battery Rooms Gas Cabinets |
FM, CSA, and ATEX approved. NEMA 4X weatherproof, dust-tight, watertight (IP66). |
|
SPARK & FLAME DETECTORS |
|||
|
Model |
Brief Description |
Suggested Applications |
Hazardous Area Certification |
|
IR
16502 |
IR Spark & Flame Detector with Glass Reinforced Polycarbonate housing to IP65, rear viewing, DIN Rail Mounting. |
Ducting conveying waste material such as sawdust, cotton and other similar waste materials conveyed in ducts. |
None |
|
IR
16500 |
IR Spark & Flame Detector with Glass Reinforced Polycarbonate housing to IP65, rear viewing, Bayonet Mounting. |
As above |
None |
|
IR
16580 |
IR Spark & Flame Detector with Die Cast Zinc Alloy (ZA12) housing to IP65, rear viewing, Bayonet Mounting. |
As Above |
None |
|
IR
16280 |
Similar in appearance to 16580. IR Spark & Flame Detector with Die Cast Zinc Alloy (ZA12) housing to IP65, rear viewing, Bayonet Mounting, for continuous operation at temperatures up to 85°C. |
As above |
None |
|
IR
16550 |
Similar in appearance to 16500. IR Spark & Flame Detector with Glass Reinforced Polycarbonate housing to IP65, rear viewing, Bayonet Mounting. |
As Above |
Intrinsically Safe (IS), certified to ATEX II 1 G and CENELEC / IEC EEx ia IIC T4 |
|
IR
16570 |
Similar in appearance to 16580. IR Spark & Flame Detector with Die Cast Zinc Alloy (ZA12) housing to IP65, rear viewing, Bayonet Mounting. |
As Above |
Intrinsically Safe (IS), certified to ATEX II 1 G and CENELEC / IEC EEx ia IIC T4 |
|
IR²
16504 |
Similar in appearance to 16502. IR Spark & Flame Detector with Glass Reinforced Polycarbonate housing to IP65, rear viewing, DIN Rail Mounting. |
As Above |
None |
|
IR²
16587 |
Similar in appearance to 16580. IR Spark & Flame Detector with Die Cast Zinc Alloy (ZA12) housing to IP65, rear viewing, Bayonet Mounting. |
As above |
None |
|
IR²
16557 |
Similar in appearance to 16500. IR Spark & Flame Detector with Glass Reinforced Polycarbonate housing to IP65, rear viewing, Bayonet Mounting. |
As Above |
Intrinsically Safe (IS), certified to ATEX II 1 G and CENELEC / IEC EEx ia IIC T4 |
|
IR²
16577 |
Similar in appearance to 16580. IR Spark & Flame Detector with Die Cast Zinc Alloy (ZA12) housing to IP65, rear viewing, Bayonet Mounting. |
As Above |
Intrinsically Safe (IS), certified to ATEX II 1 G and CENELEC / IEC EEx ia IIC T4 |