Text Box: Model 4 UV Flame Simulator
(UV Test Torch)
Text Box: SPECIFICATION

Power supply :      2 x standard Alkaline D size
                              batteries.

Spectral range:                             185 to 400nm.

Weight with batteries, 
carrying case + spare batteries:      2.2kg.
Text Box: On receipt, open carefully taking care not to damage the quartz window on the front of the unit.   Replacement quartz windows are costly!   

CAUTION

1. These Flame Simulators emit ultraviolet light
    harmful to the eyes if viewed directly.   
    
DO NOT:  Point the unit directly at any person 
                 when pressing the ON button.

DO NOT:  Open the front section containing the
                 reflector and UV emitter as a high
                 voltage is present.  This also invalidates
                 the warranty!    

2. When not in use,  ensure the unit is stored in a
    cool dry dust free location.

3. Handle the unit as you would a fragile instrument.
Text Box: OPERATION

1. Ensure the unit is fitted with fresh batteries  
    (Qty. 2 x Alkaline “D” cells).

2. To operate the unit, depress the switch and aim 
    the unit at the UV Flame Detector under test,
    ensuring it is within approximately 10 metres 
    from the front of the Test Torch.

    Distance from detector under test will vary 
    depending on the sensitivity of the UV Flame 
    Detector.   Ensure detector quartz window is 
    clean.   If the detector under test has a sensitivity 
    adjustment, note current setting and change to 
    maximum sensitivity.

3. With the switch depressed, the red LED on the 
    front of the unit should illuminate and the UV 
    Flame Detector should activate.

4. All UV sensor tubes degrade with time.  If it is 
    necessary to get very close to the detector for it 
    to activate, consider replacement of the UV 
    sensor tube.   Ideally, compare activation to a 
    new unit of known sensitivity at the same 
    distance.   On completion of tests, reset detector 
    sensitivity adjustment to original setting.

MAINTENANCE

Ensure quartz window is clean and free from oil and grease.   If necessary, gently clean with a damp cloth moistened with clean water and a minute amount of washing up liquid.

Avoid contamination of the quartz window with oil, grease and silicones which will inhibit the output.
Text Box: Please do not hesitate to contact us if further information is required:
Text Box: Intronics
122 Broadmead
Tunbridge Wells              
Kent   TN2 5RW    
ENGLAND

Tel. +44 (0) 1892 516366 
Fax +44 (0) 1892 512212

e.mail: sales@intronics.co.uk